FM Transmitter Measurement Report
Created: 2024-09-01 00-18-03
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
Frequency |
Signal
Reception |
Station
Name |
99.60 MHz |
5/5, 67 dBuV |
Classic |
Pilot |
RDS |
Phase
Difference |
6.9 kHz |
3.0 kHz |
84 deg |
|
Frequency Deviation
Limit |
Measuring
Tolerance |
75,0 kHz |
1,0 kHz |
MIN
Hold |
Max. Samples at |
Total
Samples |
% above 76,0
kHz |
9 kHz |
63 kHz |
19093 |
0,0052 |
|
Modulation Power
Limit |
Measuring
Tolerance |
12,0 dBr |
0,2 dBr |
MIN |
AVE |
MAX |
% above
12,2 dBr |
-1,9 dBr |
1,05 dBr |
2,6 dBr |
0,0 |
|
Radio Data System
PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
"Classic " |
62A1 |
13 (Light M) |
1 |
0 |
1 |
1 |
--:-- |
RT |
"Chamber Orchestra of Europe, Chamber Orchestra of Europe " |
AF |
EON |
94.8, 96.2, 99.6, 107.4 MHz |
- |
|
|